M&M Compliance Training
The Authorised Person (LV) has control of the low voltage system and the work carried out on it. The Competent Person (LV) carries out defined work under that control. HTM 06-02, NHS England's guidance on electrical safety for low voltage systems (updated October 2023), gives the Authorised Person responsibility for the practical implementation of the HTM and for the systems they are appointed to; they control the work, issue and cancel safety documents, keep the LV site logbook, and appoint Competent Persons. The Competent Person is appointed in writing by an Authorised Person to carry out defined work and accepts a safety document for that work.
Both appointments last a maximum of three years. The difference is who makes them. An Authorised Person (LV) is appointed by the Designated Person on the recommendation of the independent Authorising Engineer (LV). A Competent Person (LV) is appointed by an Authorised Person (LV). The AP is responsible for controlling the system and managing the electrical safety arrangements; the CP carries out defined work under the AP's control.
The Authorised Person decides whether the work can be done safely and on what terms. The Competent Person does it on those terms. Confuse the two and the permit system stops meaning anything.
Designated Person
Board-level owner. Appoints the AE and, on the AE's recommendation, the APs.
Authorising Engineer (LV)
Independent adviser, appointed for up to five years. Recommends APs, audits at intervals not exceeding 12 months.
Authorised Person (LV)
Controls the system. Issues safety documents, keeps the logbook, appoints and monitors CPs. One acts as Duty AP at any time.
Competent Person (LV)
Does the defined work under a safety document. Appointed in writing by an AP for up to three years
Two supporting roles complete the picture. The Duty Authorised Person (LV) is simply the Authorised Person on site who currently holds responsibility for the system: where several Authorised Persons are appointed, only one acts as Duty Authorised Person at any time, their name is displayed prominently, and handovers are recorded in the LV site logbook. The Accompanying Safety Person (LV) is someone not involved in the work, trained in emergency first aid, who keeps watch during live work, testing and proving dead.
HTM 06-02 paragraph 4.14 makes the Authorised Person (LV) responsible for the practical implementation and operation of the HTM and for the systems and installations they are appointed for. Their instructions and decisions on electrical matters may be treated as final; in a dispute they stop the work and refer it to the Authorising Engineer (LV) for adjudication.
The duties summarised at paragraph 4.18 are the job description. The Authorised Person controls the work on low voltage systems and prepares inspection, maintenance and safety programmes; ensures alterations do not compromise the system; keeps maintenance, testing and commissioning records up to date; records all switching in the LV site logbook; ensures that any person working on the system is competent to do so; maintains test equipment; cooperates with the Authorising Engineer on policy; reports dangerous occurrences in writing to the Designated Person and Authorising Engineer; appoints Competent Persons in writing, keeps the register and defines their duties on the certificate; inspects switchrooms routinely and keeps safety signage in place; and issues and cancels safety documents.
Paragraph 4.20 adds the contractor dimension: the Authorised Person confirms the competencies of LV contractors and obtains letters of competency from their employers, and, when necessary, assesses a Skilled Person (LV) for defined work on defined equipment. Paragraph 4.21 requires the Authorised Person to monitor every Competent Person's performance, including switchroom visits every three months.
Appointment follows paragraph 4.38: formally by the Designated Person, on the recommendation of the Authorising Engineer (LV), for periods not exceeding three years, on a certificate signed by all three parties. The appointment is reviewed every three years (paragraph 4.40), and in between the Authorising Engineer audits performance at intervals not exceeding 12 months, reviews the Authorised Person's operational experience against the operating records and recommends refresher training as necessary. Suspension or cancellation for safety reasons sits with the Authorising Engineer (paragraph 4.41).
The definition at paragraph 2.9 is a person who possesses, as appropriate to the work, adequate education, training and practical skills, who is able to prevent danger or injury, who has been formally appointed in writing by an Authorised Person (LV), and who accepts a safety document for defined work. That defined work may be electrical work on the system under the Authorised Person's control, but it may equally be non-electrical tasks in areas under that control, and any restrictions should be recorded on the certificate of appointment.
The Competent Person's duties while holding a safety document (paragraph 4.25) are about discipline rather than decision-making: be fully conversant with the work; read the safety document and confirm it is understood; keep to its conditions and make others do the same; keep the document and any keys in safe custody; provide personal supervision when in charge; and, if a hazard arises, withdraw everyone and report immediately to the Duty Authorised Person. A Competent Person may not work under a safety document issued to another Competent Person (4.26), may not leave the work location while the defined work is in progress (4.28), and clears the document only when everyone has been withdrawn and the workplace made safe (4.29).
Appointment is by an Authorised Person (LV), in writing, for a maximum of three years, following a formal interview (paragraphs 4.44 and 4.50). To be eligible, a candidate should be competent for the systems concerned, familiar with the installations, technically knowledgeable and experienced enough to prevent danger, adequately familiar with the HTM and local rules, and hold an emergency first-aid qualification completed within the last three years (paragraph 4.49). The Authorised Person keeps a register of all appointments, with expiry dates and training records, and reviews each one at intervals not exceeding a year (paragraph 4.48).
Authorised Person (LV)
Competent Person (LV)
Core function
Controls the LV system and the work on it; practical implementation of HTM 06-02
Carries out defined work under a safety document
Appointed by
Designated Person, on the recommendation of the Authorising Engineer (LV)
An Authorised Person (LV)
Term
Not exceeding three years; certificate signed by DP, AE and AP
Not exceeding three years; certificate signed by AP and CP
Reviewed by
AE audit at intervals not exceeding 12 months; appointment review every three years
AP review at intervals not exceeding one year
Safety documents
Issues and cancels permits-to-work, limitation-of-access, LW2; completes LW1 when issuing a certificate of authorisation for live working
Accepts safety documents; completes the LW1 self-check before live work or testing
Keeps
LV site logbook, operational policy manual records, Competent Person register
The safety document and keys in safe custody for the duration of the work
Eligibility and training
Appendix 6 standard; AP course; AE assessment; refresher training as the AE recommends
Appendix 6 standard; CP course; AP interview; emergency first aid within the last three years
Suspended by
Authorised Engineer (LV)
Authorised Person (LV)
The question we are asked most often is whether someone should attend Authorised Person or Competent Person training. The roles above give the answer.
In every case the course is one input to the appointment, not the appointment itself. HTM 06-02 expects both roles to meet the standard in its Appendix 6 on qualifications and training, and then to be assessed, appointed for defined systems and kept under review.
26th - 30th Oct 2026
Authorised Person Electrical Low Voltage (HTM 06-02): five days, credit rated at SCQF Level 7 by Qualifications Scotland. Places are limited; contact the team to reserve yours
NHSScotland Assure published an updated SHTM 06-02 on 18 February 2026 (guidance version 3 and Electrical Safety Handbook version 4). The Scottish guidance states that it is derived from NHS England's HTM 06-02, with updates for Scottish terminology, legislation and policy, and it now includes the Duty Authorised Person (LV) role; its definitions of the Authorised Person (LV), Competent Person (LV) and Skilled Person (LV) match those quoted above. The Electricity at Work Regulations 1989 apply across Great Britain. Organisations in Scotland should work to the Scottish wording, which differs in places (for example, references to the NHS Premises Assurance Model are removed); we set out what changed in our article on SHTM 06-02 version 4.
The Authorised Person controls the low voltage system: they issue and cancel safety documents, keep the LV site logbook and appoint Competent Persons. The Competent Person is appointed by an Authorised Person to carry out defined work and accepts a safety document for it.
Both are for periods not exceeding three years. The Authorised Person’s appointment is reviewed every three years and audited by the Authorising Engineer at intervals not exceeding 12 months; the Competent Person’s appointment is reviewed by the Authorised Person at intervals not exceeding one year.
Yes. The route is the Authorised Person course together with relevant experience, assessment and recommendation by the Authorising Engineer (LV), and formal appointment by the Designated Person for the specific systems and installations concerned.
No. The course gives you the knowledge HTM 06-02 expects; the appointment requires the Authorising Engineer’s assessment and recommendation and the Designated Person’s signature.
We covered the wider appointment pathway, including how the Authorising Engineer’s assessment and recommendation work across all the HTM disciplines, in our article on Authorised Person training and how to become an AP in healthcare estates.
M&M Compliance Training Services delivers Authorised Person and Competent Person Electrical Low Voltage training to HTM 06-02 and SHTM 06-02, and independent Authorising Engineer (LV) support for the assessments, appointments and audits that sit around it. Our next five-day Authorised Person LV course runs 26–30 October 2026.
Published by M&M Compliance Training Services. Guidance status verified against primary sources on 11 September 2026.
We’re here to support you. Just fill out the form and one of our team members will be in touch shortly to discuss your requirements.